Determination of octanol-air partition coefficients (KOA) of fluorotelomer acrylates, perfluoroalkyl sulfonamids, and perfluoroalkylsulfonamido ethanols
Research output: Journal contributions › Journal articles › Research › peer-review
Standard
In: Journal of Chemical & Engineering Data, Vol. 54, No. 11, 11.2009, p. 3022-3025.
Research output: Journal contributions › Journal articles › Research › peer-review
Harvard
APA
Vancouver
Bibtex
}
RIS
TY - JOUR
T1 - Determination of octanol-air partition coefficients (KOA) of fluorotelomer acrylates, perfluoroalkyl sulfonamids, and perfluoroalkylsulfonamido ethanols
AU - Dreyer, Annekatrin
AU - Langer, Vera
AU - Ebinghaus, Ralf
PY - 2009/11
Y1 - 2009/11
N2 - Octanol-air partition coefficients (KOA) for three fluorotelomer acrylates (6:2 FTA, 8:2 FTA, 10:2 FTA), two perfluoroalkyl sulfonamides (n-methyl perfluorooctane sulfonamide (MeFOSA), n-ethyl perfluorooctane sulfonamide (EtFOSA)), and two perfluoroalkyl sulfonamido ethanols (n-methyl perfluorooctane sulfonamido ethanol (MeFOSE), n-ethyl perfluorooctane sulfonamido ethanol (EtFOSE)) were determined over a temperature range from (278 to 313) K using a modified generator column method. The KOA values were calculated as the ratio of the target analyte concentrations in octanol to the target analyte concentrations in octanol saturated air. Calibrated log KOA values at 298 K ranged from 4.5 (6:2 FTA) to 6.7 (EtFOSE). Log KOA values decreased with increasing temperature and increased in the order of 6:2 FTA, 8:2 FTA, 10:2 FTA, MeFOSA, MeFOSE, EtFOSA, EtFOSE. The combined uncertainty of the method applied ranged from 5.1 % (6:2 FTA) to 17.6 % (MeFOSA). The relative extended uncertainty (P ) 95 %) ranged from 11.6 % (6:2 FTA) to 39.8 % (MeFOSA), respectively.
AB - Octanol-air partition coefficients (KOA) for three fluorotelomer acrylates (6:2 FTA, 8:2 FTA, 10:2 FTA), two perfluoroalkyl sulfonamides (n-methyl perfluorooctane sulfonamide (MeFOSA), n-ethyl perfluorooctane sulfonamide (EtFOSA)), and two perfluoroalkyl sulfonamido ethanols (n-methyl perfluorooctane sulfonamido ethanol (MeFOSE), n-ethyl perfluorooctane sulfonamido ethanol (EtFOSE)) were determined over a temperature range from (278 to 313) K using a modified generator column method. The KOA values were calculated as the ratio of the target analyte concentrations in octanol to the target analyte concentrations in octanol saturated air. Calibrated log KOA values at 298 K ranged from 4.5 (6:2 FTA) to 6.7 (EtFOSE). Log KOA values decreased with increasing temperature and increased in the order of 6:2 FTA, 8:2 FTA, 10:2 FTA, MeFOSA, MeFOSE, EtFOSA, EtFOSE. The combined uncertainty of the method applied ranged from 5.1 % (6:2 FTA) to 17.6 % (MeFOSA). The relative extended uncertainty (P ) 95 %) ranged from 11.6 % (6:2 FTA) to 39.8 % (MeFOSA), respectively.
KW - Chemistry
UR - http://www.scopus.com/inward/record.url?scp=72449162239&partnerID=8YFLogxK
U2 - 10.1021/je900082g
DO - 10.1021/je900082g
M3 - Journal articles
AN - SCOPUS:72449162239
VL - 54
SP - 3022
EP - 3025
JO - Journal of Chemical & Engineering Data
JF - Journal of Chemical & Engineering Data
SN - 0021-9568
IS - 11
ER -