Direct comparison of capillary electrophoresis and capillary liquid chromatography hyphenated to collision-cell inductively coupled plasma mass spectrometry for the investigation of Cd-, Cu- and Zn-containing metalloproteins
Publikation: Beiträge in Zeitschriften › Zeitschriftenaufsätze › Forschung
Standard
in: Journal of Chromatography A, Jahrgang 1114, Nr. 1, 05.05.2006, S. 138-144.
Publikation: Beiträge in Zeitschriften › Zeitschriftenaufsätze › Forschung
Harvard
APA
Vancouver
Bibtex
}
RIS
TY - JOUR
T1 - Direct comparison of capillary electrophoresis and capillary liquid chromatography hyphenated to collision-cell inductively coupled plasma mass spectrometry for the investigation of Cd-, Cu- and Zn-containing metalloproteins
AU - Montes-Bayon, Maria
AU - Pröfrock, Daniel
AU - Sanz-Medel, Alfredo
AU - Prange, Andreas
N1 - Funding Information: The authors want to thank Anje Kakuschke for the valuable discussions and Simone Griesel for the measurements with TXRF. Also the Spanish Ministry of Education and Science for the contract of M.M.B.
PY - 2006/5/5
Y1 - 2006/5/5
N2 - Capillary liquid chromatography (cLC) and capillary electrophoresis (CE) have been critically compared for the separation of metalloproteins when using collision-cell inductively coupled plasma mass spectrometry (ICP-CC-MS) as detection system. For cLC separation, the selected column was a C 8 (0.3 mm I.D.) and the separation conditions involved a gradient up to 80% methanol in 10 mM ammonium acetate buffer (pH 7.4). The low flow rate used (3 μL min -1) permitted the utilization of a high methanol content maintaining the sensitivity along the whole chromatographic run. For this purpose, a new low-flow interface has been developed based on a total consumption nebulizer. Similarly, CE has been studied as separation technique using a 75 μm I.D. fused silica capillary and a running buffer of 20 mM Tris-HNO 3 (pH 7.4) and working at 30 kV. Metallothionein (mixture of MT-I and -II) and superoxide dismutase (SOD) have been used as protein models in order to evaluate the separation/detection capabilities using the same injection volumes in both systems (20 nL). For both hybrid systems, separation parameters such as retention factor, numbers of theoretical plates, tailing factor and resolution have been critically compared. Also, the analytical performance characteristics of both hybrid systems have been evaluated and tested by analyzing the Cu-, Zn-species present in red blood cell extracts in order to explore more adequate separation methodology for the analysis of metalloproteins in complex matrices.
AB - Capillary liquid chromatography (cLC) and capillary electrophoresis (CE) have been critically compared for the separation of metalloproteins when using collision-cell inductively coupled plasma mass spectrometry (ICP-CC-MS) as detection system. For cLC separation, the selected column was a C 8 (0.3 mm I.D.) and the separation conditions involved a gradient up to 80% methanol in 10 mM ammonium acetate buffer (pH 7.4). The low flow rate used (3 μL min -1) permitted the utilization of a high methanol content maintaining the sensitivity along the whole chromatographic run. For this purpose, a new low-flow interface has been developed based on a total consumption nebulizer. Similarly, CE has been studied as separation technique using a 75 μm I.D. fused silica capillary and a running buffer of 20 mM Tris-HNO 3 (pH 7.4) and working at 30 kV. Metallothionein (mixture of MT-I and -II) and superoxide dismutase (SOD) have been used as protein models in order to evaluate the separation/detection capabilities using the same injection volumes in both systems (20 nL). For both hybrid systems, separation parameters such as retention factor, numbers of theoretical plates, tailing factor and resolution have been critically compared. Also, the analytical performance characteristics of both hybrid systems have been evaluated and tested by analyzing the Cu-, Zn-species present in red blood cell extracts in order to explore more adequate separation methodology for the analysis of metalloproteins in complex matrices.
KW - Chemistry
KW - CE
KW - cLC
KW - Collision cell-reaction cell ICP-MS
KW - Metalloproteins
UR - http://www.scopus.com/inward/record.url?scp=33646484419&partnerID=8YFLogxK
UR - https://www.mendeley.com/catalogue/ba52c89a-bdae-36a5-adbe-d6c3b6ed075d/
U2 - 10.1016/j.chroma.2006.02.028
DO - 10.1016/j.chroma.2006.02.028
M3 - Journal articles
VL - 1114
SP - 138
EP - 144
JO - Journal of Chromatography A
JF - Journal of Chromatography A
SN - 0021-9673
IS - 1
ER -