Development and characterisation of a new interface for coupling capillary LC with collision-cell ICPMS and its application for phosphorylation profiling of tryptic protein digests

Research output: Journal contributionsJournal articlesResearchpeer-review

Standard

Harvard

APA

Vancouver

Bibtex

@article{ef184b5bd103448ab24355f4a8778ba0,
title = "Development and characterisation of a new interface for coupling capillary LC with collision-cell ICPMS and its application for phosphorylation profiling of tryptic protein digests",
abstract = "A comparison of different nebulisers for direct hyphenation of capillary and nano liquid chromatography (Cap-LC, Nano-LC) and quadrupole-based collision cell inductively coupled plasma mass spectrometry (CC-ICP-MS) for phosphorylation profiling of tryptic protein digests is described. Helium was used as cell gas and specially tuned instrumental conditions were used to achieve background minimisation at the mass of phosphorus, because of kinetic energy discrimination of the interfering polyatomic ions. The proposed set-up is based on a modified capillary electrophoresis interface and a home-made 4-mL spray chamber. It enables the use of gradient conditions with a highly concentrated organic mobile phase as often used in protein phosphorylation analysis, without the need to apply membrane desolvation for removal of the organic phase or further background minimisation. No significant signal suppression or other negative effects caused by the organic mobile phase occur, because of the low flow rates used in Cap-LC and the robust plasma conditions of the CC-ICP-MS instrument. A tryptic digest of beta-casein was investigated as model compound to demonstrate the applicability of the proposed set-up for phosphorylation profiling in protein analysis using quadrupole based collision-cell ICP-MS as phosphorus-specific detector. Detection limits for phosphorylated peptides down to the sub picomole level were obtained. As a complementary technique, electrospray ionisation tandem mass spectrometry (ESI-MS-MS) with data base searching was used for further characterisation of the phosphorylated peptides detected.",
keywords = "Chemistry, Capillary-LC, Protein, Phosphorylation , Post-translational modification , ICP–MS, Hyphenation , Collision cell, Reaction cell",
author = "Daniel Profrock and P Leonhard and W Ruck and A Prange",
year = "2005",
month = jan,
doi = "10.1007/s00216-004-2930-5",
language = "English",
volume = "381",
pages = "194--204",
journal = "Analytical & Bioanalytical Chemistry",
issn = "1618-2642",
publisher = "Springer",
number = "1",

}

RIS

TY - JOUR

T1 - Development and characterisation of a new interface for coupling capillary LC with collision-cell ICPMS and its application for phosphorylation profiling of tryptic protein digests

AU - Profrock, Daniel

AU - Leonhard, P

AU - Ruck, W

AU - Prange, A

PY - 2005/1

Y1 - 2005/1

N2 - A comparison of different nebulisers for direct hyphenation of capillary and nano liquid chromatography (Cap-LC, Nano-LC) and quadrupole-based collision cell inductively coupled plasma mass spectrometry (CC-ICP-MS) for phosphorylation profiling of tryptic protein digests is described. Helium was used as cell gas and specially tuned instrumental conditions were used to achieve background minimisation at the mass of phosphorus, because of kinetic energy discrimination of the interfering polyatomic ions. The proposed set-up is based on a modified capillary electrophoresis interface and a home-made 4-mL spray chamber. It enables the use of gradient conditions with a highly concentrated organic mobile phase as often used in protein phosphorylation analysis, without the need to apply membrane desolvation for removal of the organic phase or further background minimisation. No significant signal suppression or other negative effects caused by the organic mobile phase occur, because of the low flow rates used in Cap-LC and the robust plasma conditions of the CC-ICP-MS instrument. A tryptic digest of beta-casein was investigated as model compound to demonstrate the applicability of the proposed set-up for phosphorylation profiling in protein analysis using quadrupole based collision-cell ICP-MS as phosphorus-specific detector. Detection limits for phosphorylated peptides down to the sub picomole level were obtained. As a complementary technique, electrospray ionisation tandem mass spectrometry (ESI-MS-MS) with data base searching was used for further characterisation of the phosphorylated peptides detected.

AB - A comparison of different nebulisers for direct hyphenation of capillary and nano liquid chromatography (Cap-LC, Nano-LC) and quadrupole-based collision cell inductively coupled plasma mass spectrometry (CC-ICP-MS) for phosphorylation profiling of tryptic protein digests is described. Helium was used as cell gas and specially tuned instrumental conditions were used to achieve background minimisation at the mass of phosphorus, because of kinetic energy discrimination of the interfering polyatomic ions. The proposed set-up is based on a modified capillary electrophoresis interface and a home-made 4-mL spray chamber. It enables the use of gradient conditions with a highly concentrated organic mobile phase as often used in protein phosphorylation analysis, without the need to apply membrane desolvation for removal of the organic phase or further background minimisation. No significant signal suppression or other negative effects caused by the organic mobile phase occur, because of the low flow rates used in Cap-LC and the robust plasma conditions of the CC-ICP-MS instrument. A tryptic digest of beta-casein was investigated as model compound to demonstrate the applicability of the proposed set-up for phosphorylation profiling in protein analysis using quadrupole based collision-cell ICP-MS as phosphorus-specific detector. Detection limits for phosphorylated peptides down to the sub picomole level were obtained. As a complementary technique, electrospray ionisation tandem mass spectrometry (ESI-MS-MS) with data base searching was used for further characterisation of the phosphorylated peptides detected.

KW - Chemistry

KW - Capillary-LC

KW - Protein

KW - Phosphorylation

KW - Post-translational modification

KW - ICP–MS

KW - Hyphenation

KW - Collision cell

KW - Reaction cell

UR - http://www.scopus.com/inward/record.url?scp=13844267041&partnerID=8YFLogxK

U2 - 10.1007/s00216-004-2930-5

DO - 10.1007/s00216-004-2930-5

M3 - Journal articles

C2 - 15592818

VL - 381

SP - 194

EP - 204

JO - Analytical & Bioanalytical Chemistry

JF - Analytical & Bioanalytical Chemistry

SN - 1618-2642

IS - 1

ER -