Determination of the antifungal agent posaconazole in human serum by HPLC with parallel column-switching technique

Research output: Journal contributionsJournal articlesResearchpeer-review

Standard

Determination of the antifungal agent posaconazole in human serum by HPLC with parallel column-switching technique. / Neubauer, Werner Christian; König, Armin; Bolek, Richard et al.

In: Journal of Chromatography B, Vol. 877, No. 24, 15.08.2009, p. 2493-2498.

Research output: Journal contributionsJournal articlesResearchpeer-review

Harvard

APA

Vancouver

Neubauer WC, König A, Bolek R, Trittler R, Engelhardt M, Jung M et al. Determination of the antifungal agent posaconazole in human serum by HPLC with parallel column-switching technique. Journal of Chromatography B. 2009 Aug 15;877(24):2493-2498. doi: 10.1016/j.jchromb.2009.06.022

Bibtex

@article{f476864b3a454adc9cfb21801c65dfe6,
title = "Determination of the antifungal agent posaconazole in human serum by HPLC with parallel column-switching technique",
abstract = "Posaconazole is a new broad-spectrum antifungal agent that is currently only available as an oral suspension and shows high intra- and inter-individual differences in oral bioavailibility. Pre-existing methods for the determination of the substance involve the use of internal standards or require a quite complicated and time-consuming sample pre-treatment. Our HPLC method is fast and fully-automated and there is no need for any manual sample pre-treatment. On-line transfer of posaconazole from the extraction column was followed by chromatographic separation on a C18 column and fluorescence detection (λex: 261 nm, λem: 357 nm). Retention time of posaconazole was about 11.7 min, the lower limit of quantification was found to be 0.1 mg/l. A linear calibration curve was obtained over the concentration range of 0.1-5 mg/l using a 50 μl sample (r2 = 0.999). The relative standard deviations of intra-day variations ranged from 2.3% to 9.4%, intra-day accuracy from 88.8% to 114.8%. {\textcopyright} 2009 Elsevier B.V. All rights reserved.",
keywords = "Chemistry, posaconazole, posaconazole, Antifungal Agents, Chromatography, High Pressure Liquid, Humans, Sensitivity and Specificity, Triazoles, Bioavailability, Column-switching, HPLC, On-line sample preparation, Posaconazole, Serum, Bioavailability, Column-switching, HPLC, On-line sample preparation, Posaconazole, Serum",
author = "Neubauer, {Werner Christian} and Armin K{\"o}nig and Richard Bolek and Rainer Trittler and Monika Engelhardt and Manfred Jung and Klaus K{\"u}mmerer",
year = "2009",
month = aug,
day = "15",
doi = "10.1016/j.jchromb.2009.06.022",
language = "English",
volume = "877",
pages = "2493--2498",
journal = "Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences",
issn = "1570-0232",
publisher = "Elsevier B.V.",
number = "24",

}

RIS

TY - JOUR

T1 - Determination of the antifungal agent posaconazole in human serum by HPLC with parallel column-switching technique

AU - Neubauer, Werner Christian

AU - König, Armin

AU - Bolek, Richard

AU - Trittler, Rainer

AU - Engelhardt, Monika

AU - Jung, Manfred

AU - Kümmerer, Klaus

PY - 2009/8/15

Y1 - 2009/8/15

N2 - Posaconazole is a new broad-spectrum antifungal agent that is currently only available as an oral suspension and shows high intra- and inter-individual differences in oral bioavailibility. Pre-existing methods for the determination of the substance involve the use of internal standards or require a quite complicated and time-consuming sample pre-treatment. Our HPLC method is fast and fully-automated and there is no need for any manual sample pre-treatment. On-line transfer of posaconazole from the extraction column was followed by chromatographic separation on a C18 column and fluorescence detection (λex: 261 nm, λem: 357 nm). Retention time of posaconazole was about 11.7 min, the lower limit of quantification was found to be 0.1 mg/l. A linear calibration curve was obtained over the concentration range of 0.1-5 mg/l using a 50 μl sample (r2 = 0.999). The relative standard deviations of intra-day variations ranged from 2.3% to 9.4%, intra-day accuracy from 88.8% to 114.8%. © 2009 Elsevier B.V. All rights reserved.

AB - Posaconazole is a new broad-spectrum antifungal agent that is currently only available as an oral suspension and shows high intra- and inter-individual differences in oral bioavailibility. Pre-existing methods for the determination of the substance involve the use of internal standards or require a quite complicated and time-consuming sample pre-treatment. Our HPLC method is fast and fully-automated and there is no need for any manual sample pre-treatment. On-line transfer of posaconazole from the extraction column was followed by chromatographic separation on a C18 column and fluorescence detection (λex: 261 nm, λem: 357 nm). Retention time of posaconazole was about 11.7 min, the lower limit of quantification was found to be 0.1 mg/l. A linear calibration curve was obtained over the concentration range of 0.1-5 mg/l using a 50 μl sample (r2 = 0.999). The relative standard deviations of intra-day variations ranged from 2.3% to 9.4%, intra-day accuracy from 88.8% to 114.8%. © 2009 Elsevier B.V. All rights reserved.

KW - Chemistry

KW - posaconazole

KW - posaconazole

KW - Antifungal Agents

KW - Chromatography, High Pressure Liquid

KW - Humans

KW - Sensitivity and Specificity

KW - Triazoles

KW - Bioavailability

KW - Column-switching

KW - HPLC

KW - On-line sample preparation

KW - Posaconazole

KW - Serum

KW - Bioavailability

KW - Column-switching

KW - HPLC

KW - On-line sample preparation

KW - Posaconazole

KW - Serum

UR - http://www.scopus.com/inward/record.url?scp=67650726438&partnerID=8YFLogxK

UR - https://www.mendeley.com/catalogue/98d7bc4b-7d88-34a5-b87d-6815c07fb563/

U2 - 10.1016/j.jchromb.2009.06.022

DO - 10.1016/j.jchromb.2009.06.022

M3 - Journal articles

C2 - 19577524

VL - 877

SP - 2493

EP - 2498

JO - Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences

JF - Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences

SN - 1570-0232

IS - 24

ER -