A new fully integrated X-ray irradiator system for dosimetric research

Research output: Journal contributionsJournal articlesResearchpeer-review

Standard

A new fully integrated X-ray irradiator system for dosimetric research. / Richter, D.; Mittelstraß, D.; Kreutzer, S. et al.
In: Applied Radiation and Isotopes, Vol. 112, 01.06.2016, p. 122-130.

Research output: Journal contributionsJournal articlesResearchpeer-review

Harvard

Richter, D, Mittelstraß, D, Kreutzer, S, Pintaske, R, Dornich, K & Fuchs, M 2016, 'A new fully integrated X-ray irradiator system for dosimetric research', Applied Radiation and Isotopes, vol. 112, pp. 122-130. https://doi.org/10.1016/j.apradiso.2016.03.022

APA

Richter, D., Mittelstraß, D., Kreutzer, S., Pintaske, R., Dornich, K., & Fuchs, M. (2016). A new fully integrated X-ray irradiator system for dosimetric research. Applied Radiation and Isotopes, 112, 122-130. https://doi.org/10.1016/j.apradiso.2016.03.022

Vancouver

Richter D, Mittelstraß D, Kreutzer S, Pintaske R, Dornich K, Fuchs M. A new fully integrated X-ray irradiator system for dosimetric research. Applied Radiation and Isotopes. 2016 Jun 1;112:122-130. doi: 10.1016/j.apradiso.2016.03.022

Bibtex

@article{5a15e16767d4469d9dd6bbdadee3e2dc,
title = "A new fully integrated X-ray irradiator system for dosimetric research",
abstract = "A fully housed X-ray irradiator was developed for use within lexsyg or Magnettech desktop equipment. The importance of hardening of the low energy photon radiation is discussed, its performance and feasibility is empirically shown and sustained by basic numerical simulations. Results of the latter for various materials are given for different X-ray source settings in order to provide estimates on the required setup for the irradiation of different geometries and materials. A Si-photodiode provides real-time monitoring of the X-ray-irradiator designed for use in dosimetric dating and other dosimetric application where irradiation of small samples or dosemeters is required.",
keywords = "Dosimetry, Low photon energy, Luminescence, Variable dose-rate, X-ray irradiator, Biology",
author = "D. Richter and D. Mittelstra{\ss} and S. Kreutzer and R. Pintaske and K. Dornich and Matthias Fuchs",
year = "2016",
month = jun,
day = "1",
doi = "10.1016/j.apradiso.2016.03.022",
language = "English",
volume = "112",
pages = "122--130",
journal = "Applied Radiation and Isotopes",
issn = "0969-8043",
publisher = "Elsevier Ltd",

}

RIS

TY - JOUR

T1 - A new fully integrated X-ray irradiator system for dosimetric research

AU - Richter, D.

AU - Mittelstraß, D.

AU - Kreutzer, S.

AU - Pintaske, R.

AU - Dornich, K.

AU - Fuchs, Matthias

PY - 2016/6/1

Y1 - 2016/6/1

N2 - A fully housed X-ray irradiator was developed for use within lexsyg or Magnettech desktop equipment. The importance of hardening of the low energy photon radiation is discussed, its performance and feasibility is empirically shown and sustained by basic numerical simulations. Results of the latter for various materials are given for different X-ray source settings in order to provide estimates on the required setup for the irradiation of different geometries and materials. A Si-photodiode provides real-time monitoring of the X-ray-irradiator designed for use in dosimetric dating and other dosimetric application where irradiation of small samples or dosemeters is required.

AB - A fully housed X-ray irradiator was developed for use within lexsyg or Magnettech desktop equipment. The importance of hardening of the low energy photon radiation is discussed, its performance and feasibility is empirically shown and sustained by basic numerical simulations. Results of the latter for various materials are given for different X-ray source settings in order to provide estimates on the required setup for the irradiation of different geometries and materials. A Si-photodiode provides real-time monitoring of the X-ray-irradiator designed for use in dosimetric dating and other dosimetric application where irradiation of small samples or dosemeters is required.

KW - Dosimetry

KW - Low photon energy

KW - Luminescence

KW - Variable dose-rate

KW - X-ray irradiator

KW - Biology

UR - http://www.scopus.com/inward/record.url?scp=84962250725&partnerID=8YFLogxK

U2 - 10.1016/j.apradiso.2016.03.022

DO - 10.1016/j.apradiso.2016.03.022

M3 - Journal articles

C2 - 27041090

AN - SCOPUS:84962250725

VL - 112

SP - 122

EP - 130

JO - Applied Radiation and Isotopes

JF - Applied Radiation and Isotopes

SN - 0969-8043

ER -