Phase Shift APOD and POD Control Technique in Multi-Level Inverters to Mitigate Total Harmonic Distortion

Publikation: Beiträge in ZeitschriftenZeitschriftenaufsätzeForschungbegutachtet

Standard

Phase Shift APOD and POD Control Technique in Multi-Level Inverters to Mitigate Total Harmonic Distortion. / Bano, Kalsoom; Abbas, Ghulam; Hatatah, Mohammed et al.

in: Mathematics, Jahrgang 12, Nr. 5, 656, 03.2024.

Publikation: Beiträge in ZeitschriftenZeitschriftenaufsätzeForschungbegutachtet

Harvard

APA

Vancouver

Bano K, Abbas G, Hatatah M, Touti E, Emara A, Mercorelli P. Phase Shift APOD and POD Control Technique in Multi-Level Inverters to Mitigate Total Harmonic Distortion. Mathematics. 2024 Mär;12(5):656. doi: 10.3390/math12050656

Bibtex

@article{d2599655b7944d48b27b192b9bc280cc,
title = "Phase Shift APOD and POD Control Technique in Multi-Level Inverters to Mitigate Total Harmonic Distortion",
abstract = "Multi-level inverters are widely employed to generate new energy because of their huge capacity and benefits in sound control performance. One of the critical areas of study for multi-level inverters is control strategy research. In this study, the control strategy for a multi-level inverter—which is frequently employed in HVDC and FACTS systems—is designed. An asymmetrical D.C. voltage source is supplied to create the appropriate output voltage waveform with fewer total harmonic distortions (THDs) at the output voltage and current waveforms. In this work, the pulse width modulation techniques of POD (phase opposition disposition) and APOD (alternative phase opposition disposition) MC PWM are applied to a multi-level inverter to generate the seven-level output voltage waveform. This study presents an enhanced variable carrier frequency APOD control approach that can successfully lower the overall harmonic distortion rate. The design and completion of the phase-shifting POD and APOD control strategies are followed by an analysis and comparison of the THD situation under various switching frequencies and a simulation and verification of the control strategy using MATLAB simulation. The TI DSP-based control approach has been programmed. The APOD technique increases the output voltage{\textquoteright}s THD to 18.27%, while the output current waveform{\textquoteright}s THD is reduced to 15.67% by utilizing the APOD PWM technique. Using the POD PWM approach increases the total harmonic distortion (THD) of the voltage waveform by 18.06% and the output current waveform{\textquoteright}s THD by 15.45%.",
keywords = "DSP control, level-shifted APOD, level-shifted POD, THD, Engineering",
author = "Kalsoom Bano and Ghulam Abbas and Mohammed Hatatah and Ezzeddine Touti and Ahmed Emara and Paolo Mercorelli",
note = "Publisher Copyright: {\textcopyright} 2024 by the authors.",
year = "2024",
month = mar,
doi = "10.3390/math12050656",
language = "English",
volume = "12",
journal = "Mathematics",
issn = "2227-7390",
publisher = "MDPI AG",
number = "5",

}

RIS

TY - JOUR

T1 - Phase Shift APOD and POD Control Technique in Multi-Level Inverters to Mitigate Total Harmonic Distortion

AU - Bano, Kalsoom

AU - Abbas, Ghulam

AU - Hatatah, Mohammed

AU - Touti, Ezzeddine

AU - Emara, Ahmed

AU - Mercorelli, Paolo

N1 - Publisher Copyright: © 2024 by the authors.

PY - 2024/3

Y1 - 2024/3

N2 - Multi-level inverters are widely employed to generate new energy because of their huge capacity and benefits in sound control performance. One of the critical areas of study for multi-level inverters is control strategy research. In this study, the control strategy for a multi-level inverter—which is frequently employed in HVDC and FACTS systems—is designed. An asymmetrical D.C. voltage source is supplied to create the appropriate output voltage waveform with fewer total harmonic distortions (THDs) at the output voltage and current waveforms. In this work, the pulse width modulation techniques of POD (phase opposition disposition) and APOD (alternative phase opposition disposition) MC PWM are applied to a multi-level inverter to generate the seven-level output voltage waveform. This study presents an enhanced variable carrier frequency APOD control approach that can successfully lower the overall harmonic distortion rate. The design and completion of the phase-shifting POD and APOD control strategies are followed by an analysis and comparison of the THD situation under various switching frequencies and a simulation and verification of the control strategy using MATLAB simulation. The TI DSP-based control approach has been programmed. The APOD technique increases the output voltage’s THD to 18.27%, while the output current waveform’s THD is reduced to 15.67% by utilizing the APOD PWM technique. Using the POD PWM approach increases the total harmonic distortion (THD) of the voltage waveform by 18.06% and the output current waveform’s THD by 15.45%.

AB - Multi-level inverters are widely employed to generate new energy because of their huge capacity and benefits in sound control performance. One of the critical areas of study for multi-level inverters is control strategy research. In this study, the control strategy for a multi-level inverter—which is frequently employed in HVDC and FACTS systems—is designed. An asymmetrical D.C. voltage source is supplied to create the appropriate output voltage waveform with fewer total harmonic distortions (THDs) at the output voltage and current waveforms. In this work, the pulse width modulation techniques of POD (phase opposition disposition) and APOD (alternative phase opposition disposition) MC PWM are applied to a multi-level inverter to generate the seven-level output voltage waveform. This study presents an enhanced variable carrier frequency APOD control approach that can successfully lower the overall harmonic distortion rate. The design and completion of the phase-shifting POD and APOD control strategies are followed by an analysis and comparison of the THD situation under various switching frequencies and a simulation and verification of the control strategy using MATLAB simulation. The TI DSP-based control approach has been programmed. The APOD technique increases the output voltage’s THD to 18.27%, while the output current waveform’s THD is reduced to 15.67% by utilizing the APOD PWM technique. Using the POD PWM approach increases the total harmonic distortion (THD) of the voltage waveform by 18.06% and the output current waveform’s THD by 15.45%.

KW - DSP control

KW - level-shifted APOD

KW - level-shifted POD

KW - THD

KW - Engineering

UR - http://www.scopus.com/inward/record.url?scp=85187419248&partnerID=8YFLogxK

U2 - 10.3390/math12050656

DO - 10.3390/math12050656

M3 - Journal articles

AN - SCOPUS:85187419248

VL - 12

JO - Mathematics

JF - Mathematics

SN - 2227-7390

IS - 5

M1 - 656

ER -