Comparison of an Electrochemical and Luminescence-Based Oxygen Measuring System for Use in the Biodegradability Testing According to Closed Bottle Test (OECD 301D)

Publikation: Beiträge in ZeitschriftenZeitschriftenaufsätzeForschungbegutachtet

Standard

Comparison of an Electrochemical and Luminescence-Based Oxygen Measuring System for Use in the Biodegradability Testing According to Closed Bottle Test (OECD 301D). / Friedrich, Judith; Längin, Andreas; Kümmerer, Klaus.

in: Clean - Soil, Air, Water, Jahrgang 41, Nr. 3, 03.2013, S. 251-257.

Publikation: Beiträge in ZeitschriftenZeitschriftenaufsätzeForschungbegutachtet

Harvard

APA

Vancouver

Bibtex

@article{f817b38146aa4819b22fab05aa7a8e50,
title = "Comparison of an Electrochemical and Luminescence-Based Oxygen Measuring System for Use in the Biodegradability Testing According to Closed Bottle Test (OECD 301D)",
abstract = "The effects of persistent organic pollutants on the aquatic environment still can hardly be assessed. Therefore, ready biodegradability is a desired key characteristic of chemicals. Accordingly, biodegradation testing is of utmost importance and is a vital part within the risk assessment for organic chemicals. In the closed bottle test (CBT; OECD 301D) the degree of biological degradation of a chemical is assessed by monitoring the oxygen consumption so far with a Clark electrode as standard method. However, this method is time-consuming, laborious and led to frequent fluctuations of the test results, which limited their validity. Due to these shortcomings, an optical system that enables contact-free measuring of the oxygen concentration in a closed bottle, based on dynamic luminescence quenching, was examined. The test results were compared to those obtained with the “classical” electrochemical technique (Clark electrode). At first, a basic standard for the handling of the new instrument in the laboratory was developed. Then possible influencing factors, reliability, comparability, and reproducibility of the test results were investigated by running the CBTs in parallel with the electrode and optode method. The findings proved the new optode method to be unambiguously superior to the electrode technique. The frequency of fluctuations of the test results and time and effort necessary for the test run could considerably be reduced. The degradation kinetics of the test substances could be followed easily in the CBT by increasing the measuring points without much additional effort.",
keywords = "Chemistry, Clark electrode, Closed Bottle test, Luminescence quenching, Optode, Oxygen measuring",
author = "Judith Friedrich and Andreas L{\"a}ngin and Klaus K{\"u}mmerer",
year = "2013",
month = mar,
doi = "10.1002/clen.201100558",
language = "English",
volume = "41",
pages = "251--257",
journal = "Clean - Soil, Air, Water",
issn = "1863-0650",
publisher = "Wiley-VCH Verlag",
number = "3",

}

RIS

TY - JOUR

T1 - Comparison of an Electrochemical and Luminescence-Based Oxygen Measuring System for Use in the Biodegradability Testing According to Closed Bottle Test (OECD 301D)

AU - Friedrich, Judith

AU - Längin, Andreas

AU - Kümmerer, Klaus

PY - 2013/3

Y1 - 2013/3

N2 - The effects of persistent organic pollutants on the aquatic environment still can hardly be assessed. Therefore, ready biodegradability is a desired key characteristic of chemicals. Accordingly, biodegradation testing is of utmost importance and is a vital part within the risk assessment for organic chemicals. In the closed bottle test (CBT; OECD 301D) the degree of biological degradation of a chemical is assessed by monitoring the oxygen consumption so far with a Clark electrode as standard method. However, this method is time-consuming, laborious and led to frequent fluctuations of the test results, which limited their validity. Due to these shortcomings, an optical system that enables contact-free measuring of the oxygen concentration in a closed bottle, based on dynamic luminescence quenching, was examined. The test results were compared to those obtained with the “classical” electrochemical technique (Clark electrode). At first, a basic standard for the handling of the new instrument in the laboratory was developed. Then possible influencing factors, reliability, comparability, and reproducibility of the test results were investigated by running the CBTs in parallel with the electrode and optode method. The findings proved the new optode method to be unambiguously superior to the electrode technique. The frequency of fluctuations of the test results and time and effort necessary for the test run could considerably be reduced. The degradation kinetics of the test substances could be followed easily in the CBT by increasing the measuring points without much additional effort.

AB - The effects of persistent organic pollutants on the aquatic environment still can hardly be assessed. Therefore, ready biodegradability is a desired key characteristic of chemicals. Accordingly, biodegradation testing is of utmost importance and is a vital part within the risk assessment for organic chemicals. In the closed bottle test (CBT; OECD 301D) the degree of biological degradation of a chemical is assessed by monitoring the oxygen consumption so far with a Clark electrode as standard method. However, this method is time-consuming, laborious and led to frequent fluctuations of the test results, which limited their validity. Due to these shortcomings, an optical system that enables contact-free measuring of the oxygen concentration in a closed bottle, based on dynamic luminescence quenching, was examined. The test results were compared to those obtained with the “classical” electrochemical technique (Clark electrode). At first, a basic standard for the handling of the new instrument in the laboratory was developed. Then possible influencing factors, reliability, comparability, and reproducibility of the test results were investigated by running the CBTs in parallel with the electrode and optode method. The findings proved the new optode method to be unambiguously superior to the electrode technique. The frequency of fluctuations of the test results and time and effort necessary for the test run could considerably be reduced. The degradation kinetics of the test substances could be followed easily in the CBT by increasing the measuring points without much additional effort.

KW - Chemistry

KW - Clark electrode

KW - Closed Bottle test

KW - Luminescence quenching

KW - Optode

KW - Oxygen measuring

UR - https://www.scopus.com/record/display.uri?eid=2-s2.0-84874738202&origin=inward&txGid=0

U2 - 10.1002/clen.201100558

DO - 10.1002/clen.201100558

M3 - Journal articles

VL - 41

SP - 251

EP - 257

JO - Clean - Soil, Air, Water

JF - Clean - Soil, Air, Water

SN - 1863-0650

IS - 3

ER -

DOI