Combining an Internal SMC with an External MTPA Control Loop for an Interior PMSM. / Zwerger, Tanja; Mercorelli, Paolo.

Proceedings of the 2018 23rd International Conference on Methods and Models in Automation and Robotics, MMAR 2018. IEEE - Institute of Electrical and Electronics Engineers Inc., 2018. S. 674-679 8485900.

Publikation: Beiträge in SammelwerkenAufsätze in KonferenzbändenForschungbegutachtet

Harvard

Zwerger, T & Mercorelli, P 2018, Combining an Internal SMC with an External MTPA Control Loop for an Interior PMSM. in Proceedings of the 2018 23rd International Conference on Methods and Models in Automation and Robotics, MMAR 2018., 8485900, IEEE - Institute of Electrical and Electronics Engineers Inc., S. 674-679, 23rd International Conference on Methods and Models in Automation and Robotics - MMAR 2018, Miedzyzdroje, Polen, 27.08.18. https://doi.org/10.1109/MMAR.2018.8485900

APA

Zwerger, T., & Mercorelli, P. (2018). Combining an Internal SMC with an External MTPA Control Loop for an Interior PMSM. in Proceedings of the 2018 23rd International Conference on Methods and Models in Automation and Robotics, MMAR 2018 (S. 674-679). [8485900] IEEE - Institute of Electrical and Electronics Engineers Inc.. https://doi.org/10.1109/MMAR.2018.8485900

Vancouver

Zwerger T, Mercorelli P. Combining an Internal SMC with an External MTPA Control Loop for an Interior PMSM. in Proceedings of the 2018 23rd International Conference on Methods and Models in Automation and Robotics, MMAR 2018. IEEE - Institute of Electrical and Electronics Engineers Inc. 2018. S. 674-679. 8485900 doi: 10.1109/MMAR.2018.8485900

Bibtex

@inbook{162fa94a0a484c7f8331c87b05b918e4,
title = "Combining an Internal SMC with an External MTPA Control Loop for an Interior PMSM",
abstract = "This paper deals with control strategies in Permanent Magnet Synchronous Machines (PMSMs). An internal loop control is proposed in which a Sliding Mode Control (SMC) works to control the optimal desired current calculated by the Maximum Torque per Ampere (MTPA) strategy which works in the external loop of control. The main contribution of the paper is to show how disturbance rejection is provided together with a load compensation. Simulation results are shown comparing, with the same control scheme, the performances obtained with SMC and Pronortional-Intezral controllers (PI).",
keywords = "MTPA, PMSMs, Sliding Mode Control Methods, Engineering",
author = "Tanja Zwerger and Paolo Mercorelli",
year = "2018",
month = oct,
day = "8",
doi = "10.1109/MMAR.2018.8485900",
language = "English",
isbn = "978-1-5386-4326-6 ",
pages = "674--679",
booktitle = "Proceedings of the 2018 23rd International Conference on Methods and Models in Automation and Robotics, MMAR 2018",
publisher = "IEEE - Institute of Electrical and Electronics Engineers Inc.",
address = "United States",
note = "23rd International Conference on Methods and Models in Automation and Robotics - MMAR 2018, MMAR 2018 ; Conference date: 27-08-2018 Through 30-08-2018",
url = "http://mmar.edu.pl/",

}

RIS

TY - CHAP

T1 - Combining an Internal SMC with an External MTPA Control Loop for an Interior PMSM

AU - Zwerger, Tanja

AU - Mercorelli, Paolo

N1 - Conference code: 23

PY - 2018/10/8

Y1 - 2018/10/8

N2 - This paper deals with control strategies in Permanent Magnet Synchronous Machines (PMSMs). An internal loop control is proposed in which a Sliding Mode Control (SMC) works to control the optimal desired current calculated by the Maximum Torque per Ampere (MTPA) strategy which works in the external loop of control. The main contribution of the paper is to show how disturbance rejection is provided together with a load compensation. Simulation results are shown comparing, with the same control scheme, the performances obtained with SMC and Pronortional-Intezral controllers (PI).

AB - This paper deals with control strategies in Permanent Magnet Synchronous Machines (PMSMs). An internal loop control is proposed in which a Sliding Mode Control (SMC) works to control the optimal desired current calculated by the Maximum Torque per Ampere (MTPA) strategy which works in the external loop of control. The main contribution of the paper is to show how disturbance rejection is provided together with a load compensation. Simulation results are shown comparing, with the same control scheme, the performances obtained with SMC and Pronortional-Intezral controllers (PI).

KW - MTPA

KW - PMSMs

KW - Sliding Mode Control Methods

KW - Engineering

UR - http://www.scopus.com/inward/record.url?scp=85056469123&partnerID=8YFLogxK

U2 - 10.1109/MMAR.2018.8485900

DO - 10.1109/MMAR.2018.8485900

M3 - Article in conference proceedings

AN - SCOPUS:85056469123

SN - 978-1-5386-4326-6

SP - 674

EP - 679

BT - Proceedings of the 2018 23rd International Conference on Methods and Models in Automation and Robotics, MMAR 2018

PB - IEEE - Institute of Electrical and Electronics Engineers Inc.

T2 - 23rd International Conference on Methods and Models in Automation and Robotics - MMAR 2018

Y2 - 27 August 2018 through 30 August 2018

ER -

DOI