Combining an Internal SMC with an External MTPA Control Loop for an Interior PMSM

Research output: Contributions to collected editions/worksArticle in conference proceedingsResearchpeer-review

Authors

This paper deals with control strategies in Permanent Magnet Synchronous Machines (PMSMs). An internal loop control is proposed in which a Sliding Mode Control (SMC) works to control the optimal desired current calculated by the Maximum Torque per Ampere (MTPA) strategy which works in the external loop of control. The main contribution of the paper is to show how disturbance rejection is provided together with a load compensation. Simulation results are shown comparing, with the same control scheme, the performances obtained with SMC and Pronortional-Intezral controllers (PI).

Original languageEnglish
Title of host publicationProceedings of the 2018 23rd International Conference on Methods and Models in Automation and Robotics, MMAR 2018
Number of pages6
PublisherIEEE - Institute of Electrical and Electronics Engineers Inc.
Publication date08.10.2018
Pages674-679
Article number8485900
ISBN (print)978-1-5386-4326-6
ISBN (electronic)978-1-5386-4325-9 , 978-1-5386-4324-2
DOIs
Publication statusPublished - 08.10.2018
Event23rd International Conference on Methods and Models in Automation and Robotics - MMAR 2018 - Amber Baltic Hotel, Miedzyzdroje, Poland
Duration: 27.08.201830.08.2018
Conference number: 23
http://mmar.edu.pl/

    Research areas

  • MTPA, PMSMs, Sliding Mode Control Methods
  • Engineering