A New, Rapid, Fully Automated Method for Determination of Fluconazole in Serum by Column-Switching Liquid Chromatography
Research output: Journal contributions › Journal articles › Research › peer-review
Standard
In: Therapeutic Drug Monitoring, Vol. 26, No. 4, 01.08.2004, p. 425-431.
Research output: Journal contributions › Journal articles › Research › peer-review
Harvard
APA
Vancouver
Bibtex
}
RIS
TY - JOUR
T1 - A New, Rapid, Fully Automated Method for Determination of Fluconazole in Serum by Column-Switching Liquid Chromatography
AU - Egle, Hannes
AU - Trittler, Rainer
AU - Kümmerer, Klaus
PY - 2004/8/1
Y1 - 2004/8/1
N2 - A sensitive and rapid HPLC assay for the determination of fluconazole in serum is described. HPLC-integrated sample preparation allows direct injection of serum samples without any pretreatment. The in-line extraction technique is carried out by automatically switching from the extraction column (Lichrospher® ADS C 8) to the analytic column (Nucleosil C 18). After 6 minutes the matrix passes the extraction column, and the retained analyte is quantitatively transferred to the analytic column, where separation by isocratic HPLC is performed. The extraction eluent is sodium dihydrogen phosphate buffer, pH 5.0 (50 mM), and the analytic eluent is acetonitrile/sodium dihydrogen phosphate buffer, pH 5.0 (50 mM) (26.8/73.2, vol/vol). Fluconazole is detected according to its absorption maximum at 210 nm. The lower limit of quantification (LLOQ) is 0.65 μg/mL, the limit of detection (LOD) is 0.2 μg/mL, and the quantification range is 0.65-23.3 μg/mL. The assay was precise with a between-run coefficient of variation of ≤ 5.59%. The within-run accuracy was 99.8% and 103.4%, and the between-run accuracy was 99.2% and 99.7%, respectively, for the concentrations 23.3 μg/mL and 1.3 μg/mL. The recovery was 78%. The described procedure allows sample cleanup and determination within 20 minutes, thereby facilitating drug monitoring in clinical routine. The method was applied successfully.
AB - A sensitive and rapid HPLC assay for the determination of fluconazole in serum is described. HPLC-integrated sample preparation allows direct injection of serum samples without any pretreatment. The in-line extraction technique is carried out by automatically switching from the extraction column (Lichrospher® ADS C 8) to the analytic column (Nucleosil C 18). After 6 minutes the matrix passes the extraction column, and the retained analyte is quantitatively transferred to the analytic column, where separation by isocratic HPLC is performed. The extraction eluent is sodium dihydrogen phosphate buffer, pH 5.0 (50 mM), and the analytic eluent is acetonitrile/sodium dihydrogen phosphate buffer, pH 5.0 (50 mM) (26.8/73.2, vol/vol). Fluconazole is detected according to its absorption maximum at 210 nm. The lower limit of quantification (LLOQ) is 0.65 μg/mL, the limit of detection (LOD) is 0.2 μg/mL, and the quantification range is 0.65-23.3 μg/mL. The assay was precise with a between-run coefficient of variation of ≤ 5.59%. The within-run accuracy was 99.8% and 103.4%, and the between-run accuracy was 99.2% and 99.7%, respectively, for the concentrations 23.3 μg/mL and 1.3 μg/mL. The recovery was 78%. The described procedure allows sample cleanup and determination within 20 minutes, thereby facilitating drug monitoring in clinical routine. The method was applied successfully.
KW - Absorption
KW - accuracy
KW - ADS
KW - ASSAY
KW - Bioassay
KW - buffer
KW - chromatography
KW - COEFFICIENT
KW - COLUMN
KW - column switching
KW - column-switching
KW - concentration
KW - detection
KW - determination
KW - direct injection
KW - DIRECT-INJECTION
KW - DOSAGE
KW - drug
KW - drug monitoring
KW - Drug-monitoring
KW - EXTRACTION
KW - FLUCONAZOLE
KW - GERMANY
KW - HPLC
KW - HPLC ASSAY
KW - human plasma
KW - in-line extraction
KW - INJECTION
KW - INTEGRATED SAMPLE PREPARATION
KW - liquid
KW - liquid chromatography
KW - LIQUID-CHROMATOGRAPHY
KW - MALIGNANCY
KW - MATRIX
KW - Method
KW - Monitoring
KW - PH
KW - pharmacokinetics
KW - PRETREATMENT
KW - QUANTIFICATION
KW - recovery
KW - RENAL REPLACEMENT THERAPY
KW - sample preparation
KW - SAMPLES
KW - SEPARATION
KW - Serum
KW - SERUM SAMPLE
KW - TANDEM MASS-SPECTROMETRY
KW - USA
KW - Chemistry
UR - http://www.scopus.com/inward/record.url?scp=3343018904&partnerID=8YFLogxK
U2 - 10.1097/00007691-200408000-00013
DO - 10.1097/00007691-200408000-00013
M3 - Journal articles
VL - 26
SP - 425
EP - 431
JO - Therapeutic Drug Monitoring
JF - Therapeutic Drug Monitoring
SN - 0163-4356
IS - 4
ER -