Standard
The Use of Anti-Windup Techniques in Didactic Level Systems: An Interesting Application. / Silva, Vinicius Berno E.; Arce, Bruno Resende; De Souza Vieira, Pedro Antonio et al.
Proceedings of the 2023 24th International Carpathian Control Conference, ICCC 2023. Hrsg. / Daniel Drotos; Rabab Benotsmane; Attila Karoly Varga; Attila Trohak; Jozsef Vasarhelyi. Institute of Electrical and Electronics Engineers Inc., 2023. S. 49-53 (Proceedings of the 2023 24th International Carpathian Control Conference, ICCC 2023).
Publikation: Beiträge in Sammelwerken › Aufsätze in Konferenzbänden › Forschung › begutachtet
Harvard
Silva, VBE, Arce, BR, De Souza Vieira, PA, Dos Santos, MF, Neto, AFS
& Mercorelli, P 2023,
The Use of Anti-Windup Techniques in Didactic Level Systems: An Interesting Application. in D Drotos, R Benotsmane, AK Varga, A Trohak & J Vasarhelyi (Hrsg.),
Proceedings of the 2023 24th International Carpathian Control Conference, ICCC 2023. Proceedings of the 2023 24th International Carpathian Control Conference, ICCC 2023, Institute of Electrical and Electronics Engineers Inc., S. 49-53, 24th International Carpathian Control Conference, Sinaia, Rumänien,
12.05.23.
https://doi.org/10.1109/ICCC57093.2023.10178982
APA
Silva, V. B. E., Arce, B. R., De Souza Vieira, P. A., Dos Santos, M. F., Neto, A. F. S.
, & Mercorelli, P. (2023).
The Use of Anti-Windup Techniques in Didactic Level Systems: An Interesting Application. In D. Drotos, R. Benotsmane, A. K. Varga, A. Trohak, & J. Vasarhelyi (Hrsg.),
Proceedings of the 2023 24th International Carpathian Control Conference, ICCC 2023 (S. 49-53). (Proceedings of the 2023 24th International Carpathian Control Conference, ICCC 2023). Institute of Electrical and Electronics Engineers Inc..
https://doi.org/10.1109/ICCC57093.2023.10178982
Vancouver
Silva VBE, Arce BR, De Souza Vieira PA, Dos Santos MF, Neto AFS
, Mercorelli P.
The Use of Anti-Windup Techniques in Didactic Level Systems: An Interesting Application. in Drotos D, Benotsmane R, Varga AK, Trohak A, Vasarhelyi J, Hrsg., Proceedings of the 2023 24th International Carpathian Control Conference, ICCC 2023. Institute of Electrical and Electronics Engineers Inc. 2023. S. 49-53. (Proceedings of the 2023 24th International Carpathian Control Conference, ICCC 2023). doi: 10.1109/ICCC57093.2023.10178982
Bibtex
@inbook{6650b367865944e78354284f429f2126,
title = "The Use of Anti-Windup Techniques in Didactic Level Systems: An Interesting Application",
abstract = "Living in the age of technology and industrial evolution, automation applications are increasingly used and more necessary, either to improve the quality of a product or even cheapen some processes. Methods of Proportional, Integral and Derivative (PID) (such as its variants) tuning controllers have been much discussed due to their effectiveness. Taking this into consideration, the proposed work aims to improve the level controller in PD3 SMAR didactic plant. This level system always presents actuator saturation which leads to overshooting of the controlled response, decreasing the quality, consequently. To avoid this problem, the Back-Calculation Anti-Windup technique was considered. The Proportional and Integral (PI) control was performed directly at the plant via MATLAB software. The results showed that the use of Anti-Windup techniques became useful and reliable in systems where the actuator saturation was strongly present.",
keywords = "Anti-Windup Techniques, Didactic Level Systems, PI Controller, Engineering",
author = "Silva, {Vinicius Berno E.} and Arce, {Bruno Resende} and {De Souza Vieira}, {Pedro Antonio} and {Dos Santos}, {Murillo Ferreira} and Neto, {Accacio Ferreira Santos} and Paolo Mercorelli",
note = "Funding Information: The authors would like to thank CEFET-MG, DAAD and Leuphana University of L{\"u}neburg for their financial support. Publisher Copyright: {\textcopyright} 2023 IEEE.; 24th International Carpathian Control Conference, ICCC 2023 ; Conference date: 12-05-2023 Through 14-05-2023",
year = "2023",
month = jun,
day = "12",
doi = "10.1109/ICCC57093.2023.10178982",
language = "English",
isbn = "979-8-3503-1023-8",
series = "Proceedings of the 2023 24th International Carpathian Control Conference, ICCC 2023",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
pages = "49--53",
editor = "Daniel Drotos and Rabab Benotsmane and Varga, {Attila Karoly} and Attila Trohak and Jozsef Vasarhelyi",
booktitle = "Proceedings of the 2023 24th International Carpathian Control Conference, ICCC 2023",
address = "United States",
}
RIS
TY - CHAP
T1 - The Use of Anti-Windup Techniques in Didactic Level Systems
T2 - 24th International Carpathian Control Conference
AU - Silva, Vinicius Berno E.
AU - Arce, Bruno Resende
AU - De Souza Vieira, Pedro Antonio
AU - Dos Santos, Murillo Ferreira
AU - Neto, Accacio Ferreira Santos
AU - Mercorelli, Paolo
N1 - Conference code: 24
PY - 2023/6/12
Y1 - 2023/6/12
N2 - Living in the age of technology and industrial evolution, automation applications are increasingly used and more necessary, either to improve the quality of a product or even cheapen some processes. Methods of Proportional, Integral and Derivative (PID) (such as its variants) tuning controllers have been much discussed due to their effectiveness. Taking this into consideration, the proposed work aims to improve the level controller in PD3 SMAR didactic plant. This level system always presents actuator saturation which leads to overshooting of the controlled response, decreasing the quality, consequently. To avoid this problem, the Back-Calculation Anti-Windup technique was considered. The Proportional and Integral (PI) control was performed directly at the plant via MATLAB software. The results showed that the use of Anti-Windup techniques became useful and reliable in systems where the actuator saturation was strongly present.
AB - Living in the age of technology and industrial evolution, automation applications are increasingly used and more necessary, either to improve the quality of a product or even cheapen some processes. Methods of Proportional, Integral and Derivative (PID) (such as its variants) tuning controllers have been much discussed due to their effectiveness. Taking this into consideration, the proposed work aims to improve the level controller in PD3 SMAR didactic plant. This level system always presents actuator saturation which leads to overshooting of the controlled response, decreasing the quality, consequently. To avoid this problem, the Back-Calculation Anti-Windup technique was considered. The Proportional and Integral (PI) control was performed directly at the plant via MATLAB software. The results showed that the use of Anti-Windup techniques became useful and reliable in systems where the actuator saturation was strongly present.
KW - Anti-Windup Techniques
KW - Didactic Level Systems
KW - PI Controller
KW - Engineering
UR - http://www.scopus.com/inward/record.url?scp=85166474020&partnerID=8YFLogxK
UR - https://www.mendeley.com/catalogue/2749ecd2-f249-3777-bb37-152c06c10ad7/
U2 - 10.1109/ICCC57093.2023.10178982
DO - 10.1109/ICCC57093.2023.10178982
M3 - Article in conference proceedings
AN - SCOPUS:85166474020
SN - 979-8-3503-1023-8
T3 - Proceedings of the 2023 24th International Carpathian Control Conference, ICCC 2023
SP - 49
EP - 53
BT - Proceedings of the 2023 24th International Carpathian Control Conference, ICCC 2023
A2 - Drotos, Daniel
A2 - Benotsmane, Rabab
A2 - Varga, Attila Karoly
A2 - Trohak, Attila
A2 - Vasarhelyi, Jozsef
PB - Institute of Electrical and Electronics Engineers Inc.
Y2 - 12 May 2023 through 14 May 2023
ER -