Detection of significant tracer gases by means of polymer gas sensors

Research output: Journal contributionsConference abstract in journalResearch

Standard

Detection of significant tracer gases by means of polymer gas sensors. / Meyer, Jürgen T.; Georgiadis, A.; Persaud, Krishna C. et al.
In: Chemie-Ingenieur-Technik, Vol. 77, No. 8, 01.08.2005, p. 1144-1144.

Research output: Journal contributionsConference abstract in journalResearch

Harvard

APA

Vancouver

Meyer JT, Georgiadis A, Persaud KC, Scorsonne E. Detection of significant tracer gases by means of polymer gas sensors. Chemie-Ingenieur-Technik. 2005 Aug 1;77(8):1144-1144. doi: 10.1002/cite.200590386

Bibtex

@article{a5db65e5f59642bab8c9a2fb97ca8377,
title = "Detection of significant tracer gases by means of polymer gas sensors",
abstract = "The detection of significant tracer gases by means of polymer gas sensors is discussed. The alarm situations have been investigated by means of Fourier transform infrared (FTIR) measurements accompanied by GC/MS measurements. An aspirating smoke detection system has been used for the control of the alarm and nuisance alarm situations. The results show that the microsystem size allows the positioning at several locations in a plant to improve the monitoring.",
keywords = "Engineering",
author = "Meyer, {J{\"u}rgen T.} and A. Georgiadis and Persaud, {Krishna C.} and Emmanuel Scorsonne",
year = "2005",
month = aug,
day = "1",
doi = "10.1002/cite.200590386",
language = "English",
volume = "77",
pages = "1144--1144",
journal = "Chemie-Ingenieur-Technik",
issn = "0009-286X",
publisher = "Wiley-VCH Verlag",
number = "8",

}

RIS

TY - JOUR

T1 - Detection of significant tracer gases by means of polymer gas sensors

AU - Meyer, Jürgen T.

AU - Georgiadis, A.

AU - Persaud, Krishna C.

AU - Scorsonne, Emmanuel

PY - 2005/8/1

Y1 - 2005/8/1

N2 - The detection of significant tracer gases by means of polymer gas sensors is discussed. The alarm situations have been investigated by means of Fourier transform infrared (FTIR) measurements accompanied by GC/MS measurements. An aspirating smoke detection system has been used for the control of the alarm and nuisance alarm situations. The results show that the microsystem size allows the positioning at several locations in a plant to improve the monitoring.

AB - The detection of significant tracer gases by means of polymer gas sensors is discussed. The alarm situations have been investigated by means of Fourier transform infrared (FTIR) measurements accompanied by GC/MS measurements. An aspirating smoke detection system has been used for the control of the alarm and nuisance alarm situations. The results show that the microsystem size allows the positioning at several locations in a plant to improve the monitoring.

KW - Engineering

UR - https://www.mendeley.com/catalogue/96f6608f-3814-3938-846e-7fd403f21ac7/

U2 - 10.1002/cite.200590386

DO - 10.1002/cite.200590386

M3 - Conference abstract in journal

VL - 77

SP - 1144

EP - 1144

JO - Chemie-Ingenieur-Technik

JF - Chemie-Ingenieur-Technik

SN - 0009-286X

IS - 8

ER -