Correlation between Isometric Maximum Strength and One Repetition Maximum in the Calf Muscle in Extended and Bended Knee Joint
Research output: Journal contributions › Journal articles › Research › peer-review
Standard
In: International Journal of Applied Sports Science, Vol. 34, No. 1, 30.06.2022, p. 61-71.
Research output: Journal contributions › Journal articles › Research › peer-review
Harvard
APA
Vancouver
Bibtex
}
RIS
TY - JOUR
T1 - Correlation between Isometric Maximum Strength and One Repetition Maximum in the Calf Muscle in Extended and Bended Knee Joint
AU - Warneke, Konstantin
AU - Hillebrecht, Martin
AU - Wirth, Klaus
AU - Keiner, Michael
AU - Schiemann, Stephan
PY - 2022/6/30
Y1 - 2022/6/30
N2 - Previous research points out high relevance of maximal strength measurement in the diagnostics of different populations. However, there is inconsistency in procedures of maximum strength measurements.Thus, it must be questioned whether the results from different studies are actually comparable. Due to the aforementioned problems in standardization, the aim of this study was to assess correlations between and reproducibility of isometric and dynamic strength testing. Since there are many studies investigating maximal strength in the calf muscles, this study will examine the plantar flexors. For this purpose, 87active participants were recruited (m: 52, f: 35, age: 28.3 ± 5.5 years, range 18-38 years, height: 178.3 ± 6.6 cm, weight: 81.5 ± 7.4 kg) who performed maximal isometric strength testing and dynamic 1RM testing in plantar flexion both with extended and bended knee joint. Pearson correlation as well asconcordance correlation coefficient (CCC) were determined. In literature, CCC is used to determine reproducibility between two different testing methods. There were correlation coefficients of r = 0.63 – 0.77 and =0.62 ‒ 0.77. Results are comparable with correlations between maximal isometric strengthand 1-RM in previous studies in different movements. In consideration of CCC, isometric strength testing and 1RM seem to not measure the same parameter, therefore comparison of results measured with different procedures seems difficult. Our results exhibit a high influence of isometric maximal strength on 1RM performance. However, 1RM tests cannot be replaced by isometric strength testing.Care must be taken due to standardization of procedure when comparing results from different studies and, especially, if 1RM testing should be replaced with isometric strength measurement.
AB - Previous research points out high relevance of maximal strength measurement in the diagnostics of different populations. However, there is inconsistency in procedures of maximum strength measurements.Thus, it must be questioned whether the results from different studies are actually comparable. Due to the aforementioned problems in standardization, the aim of this study was to assess correlations between and reproducibility of isometric and dynamic strength testing. Since there are many studies investigating maximal strength in the calf muscles, this study will examine the plantar flexors. For this purpose, 87active participants were recruited (m: 52, f: 35, age: 28.3 ± 5.5 years, range 18-38 years, height: 178.3 ± 6.6 cm, weight: 81.5 ± 7.4 kg) who performed maximal isometric strength testing and dynamic 1RM testing in plantar flexion both with extended and bended knee joint. Pearson correlation as well asconcordance correlation coefficient (CCC) were determined. In literature, CCC is used to determine reproducibility between two different testing methods. There were correlation coefficients of r = 0.63 – 0.77 and =0.62 ‒ 0.77. Results are comparable with correlations between maximal isometric strengthand 1-RM in previous studies in different movements. In consideration of CCC, isometric strength testing and 1RM seem to not measure the same parameter, therefore comparison of results measured with different procedures seems difficult. Our results exhibit a high influence of isometric maximal strength on 1RM performance. However, 1RM tests cannot be replaced by isometric strength testing.Care must be taken due to standardization of procedure when comparing results from different studies and, especially, if 1RM testing should be replaced with isometric strength measurement.
KW - Physical education and sports
UR - https://www.mendeley.com/catalogue/eee26707-4941-3990-a4a2-d3250b13d23e/
U2 - 10.24985/ijass.2022.34.1.61
DO - 10.24985/ijass.2022.34.1.61
M3 - Journal articles
VL - 34
SP - 61
EP - 71
JO - International Journal of Applied Sports Science
JF - International Journal of Applied Sports Science
SN - 2233-7946
IS - 1
ER -