Simultaneous determination of alkylphenol ethoxylates and their biotransformation products by liquid chromatography/electrospray ionisation tandem mass spectrometry
Publikation: Beiträge in Zeitschriften › Zeitschriftenaufsätze › Forschung › begutachtet
Standard
in: Journal of Chromatography A, Jahrgang 1035, Nr. 1, 30.04.2004, S. 115-122.
Publikation: Beiträge in Zeitschriften › Zeitschriftenaufsätze › Forschung › begutachtet
Harvard
APA
Vancouver
Bibtex
}
RIS
TY - JOUR
T1 - Simultaneous determination of alkylphenol ethoxylates and their biotransformation products by liquid chromatography/electrospray ionisation tandem mass spectrometry
AU - Jahnke, Annika
AU - Gandraß, Jürgen
AU - Ruck, Wolfgang
PY - 2004/4/30
Y1 - 2004/4/30
N2 - Reversed-phase LC-MS/MS is used to determine major estrogenic alkylphenol ethoxylates (APEOs) and their biotransformation products. It allows the simultaneous analysis of eight APEOs, alkylphenoxy carboxylates (APECs) and alkylphenols (APs) in sewage treatment plant (STP) effluents in the same extract after solid-phase enrichment on polymeric Oasis HLB. As precursor ions, [APEO+NH4]+, [APEC-H]- and [AP-H]- were monitored. Instrumental limits of detection (LOD) were 2-600pg, corresponding to sample concentrations of 0.04-12ngl-1, without correction for overall method recoveries. Matrix-induced signal suppression during electrospray ionisation (ESI) and extraction as well as overall method recoveries were assessed and the suitability of deuterated surrogates as internal standards was evaluated. © 2004 Elsevier B.V. All rights reserved.
AB - Reversed-phase LC-MS/MS is used to determine major estrogenic alkylphenol ethoxylates (APEOs) and their biotransformation products. It allows the simultaneous analysis of eight APEOs, alkylphenoxy carboxylates (APECs) and alkylphenols (APs) in sewage treatment plant (STP) effluents in the same extract after solid-phase enrichment on polymeric Oasis HLB. As precursor ions, [APEO+NH4]+, [APEC-H]- and [AP-H]- were monitored. Instrumental limits of detection (LOD) were 2-600pg, corresponding to sample concentrations of 0.04-12ngl-1, without correction for overall method recoveries. Matrix-induced signal suppression during electrospray ionisation (ESI) and extraction as well as overall method recoveries were assessed and the suitability of deuterated surrogates as internal standards was evaluated. © 2004 Elsevier B.V. All rights reserved.
KW - Chemistry
KW - alkylphenol ethoxylates
KW - alkylphenoxy carboxylates
KW - nonylphenol
KW - octylphenol
KW - water analysis
KW - Alkylphenol ethoxylates
KW - Octylphenol
KW - Alkylphenoxy carboxylates
KW - Water analysis
KW - Nonylphenol
UR - http://www.scopus.com/inward/record.url?scp=1842451590&partnerID=8YFLogxK
UR - https://www.mendeley.com/catalogue/ce74aa4f-aa01-3b93-963c-51f49c7c842b/
U2 - 10.1016/j.chroma.2004.02.060
DO - 10.1016/j.chroma.2004.02.060
M3 - Journal articles
VL - 1035
SP - 115
EP - 122
JO - Journal of Chromatography A
JF - Journal of Chromatography A
SN - 0021-9673
IS - 1
ER -