Microbiological and environmental effects of aquifer thermal energy storage

Publikation: Beiträge in SammelwerkenAufsätze in KonferenzbändenForschungbegutachtet

Authors

The storage of thermal energy, either heat or chill, in aquifers or impoundments creates local perturbations of the indigenous microflora and the environmental properties. Within an international working group of the International Energy Agency (IEA Annex Vl) possible environmental impacts of ATES-systems were recognized and investigated. Investigations of storage systems on natural sites, man-made aquifers and large-scale models of impounded aquifers showed changes in microbial populations, but until now no adverse microbiological processes associated with ATES-systems could be documented (Winters, 1992). However, examinations with a model system indicate an increased risk of environmental impact. Therefore, the operation of ATES-systems should be accompanied by chemical and biological investigations.

OriginalspracheEnglisch
TitelProceedings of the 27th Intersociety Energy Conversion Engineering Conference
Anzahl der Seiten6
Band4
VerlagIEEE - Institute of Electrical and Electronics Engineers Inc.
Erscheinungsdatum1992
Seiten95-100
ISBN (Print)1560912642, 978-1560912644
PublikationsstatusErschienen - 1992
Veranstaltung27th Intersociety Energy Conversion Engineering Conference - 1992 - San Diego, USA / Vereinigte Staaten
Dauer: 03.08.199207.08.1992
Konferenznummer: 27