Concentration of ciprofloxacin in Brazilian hospital effluent and preliminary risk assessment: A case study

Publikation: Beiträge in ZeitschriftenZeitschriftenaufsätzeForschungbegutachtet

Standard

Concentration of ciprofloxacin in Brazilian hospital effluent and preliminary risk assessment : A case study. / Martins, Ayrton F.; Vasconcelos, Tibiriça G. ; Henriques, Danielle M. et al.

in: Clean - Soil, Air, Water, Jahrgang 36, Nr. 3, 03.2008, S. 264-269.

Publikation: Beiträge in ZeitschriftenZeitschriftenaufsätzeForschungbegutachtet

Harvard

APA

Vancouver

Bibtex

@article{2d9aa3e775bb438994a41762f0046815,
title = "Concentration of ciprofloxacin in Brazilian hospital effluent and preliminary risk assessment: A case study",
abstract = "This study was carried out to evaluate the occurrence of the fluoroquinolone antimicrobial agent ciprofloxacin (CIP)in the effluent of the Hospital of the Federal University of Santa Maria (HUSM). Measured environmental concentrations (MECs) of CIP in the hospital wastewater, both before (P1) and after (P2) cesspit/filter system treatment (CFTS), were determined by means of solid phase extraction and reversed-phase liquid chromatography with fluorescence detection (LC-FLD) and reversed-phase liquid chromatography with mass spectrometric detection (LC-MS/MS). The MECs (n = 7 daily composed samples) were 19 to 155 μg L-1 (average: 54 ± 21 μg L-1) and 32 to 99 μg L-1 (average: 65 ± 45 μg L-1) in P1 and P2, respectively. No relevant removal was observed from P1 to P2. In a worst case scenario, the final effluent was regarded as MECs of surface water. These MECs were generally 5 to 20,000-fold higher than what was previously known. If the present data is drawn on to form a model of the situation in developing countries, the picture provides a first rough indication that the environmental risk associated with the use and emission of pharmaceuticals into the environment in developing countries might be higher than in developed countries. {\textcopyright} 2008 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.",
keywords = "Chemistry, antibiotics, fluoroquinolones, pharmaceuticals, hospital wastewater",
author = "Martins, {Ayrton F.} and Vasconcelos, {Tibiri{\c c}a G.} and Henriques, {Danielle M.} and {da Silveira Frank}, Carsten and Armin K{\"o}nig and Klaus K{\"u}mmerer",
year = "2008",
month = mar,
doi = "10.1002/clen.200700171",
language = "English",
volume = "36",
pages = "264--269",
journal = "Clean - Soil, Air, Water",
issn = "1863-0650",
publisher = "Wiley-VCH Verlag",
number = "3",

}

RIS

TY - JOUR

T1 - Concentration of ciprofloxacin in Brazilian hospital effluent and preliminary risk assessment

T2 - A case study

AU - Martins, Ayrton F.

AU - Vasconcelos, Tibiriça G.

AU - Henriques, Danielle M.

AU - da Silveira Frank, Carsten

AU - König, Armin

AU - Kümmerer, Klaus

PY - 2008/3

Y1 - 2008/3

N2 - This study was carried out to evaluate the occurrence of the fluoroquinolone antimicrobial agent ciprofloxacin (CIP)in the effluent of the Hospital of the Federal University of Santa Maria (HUSM). Measured environmental concentrations (MECs) of CIP in the hospital wastewater, both before (P1) and after (P2) cesspit/filter system treatment (CFTS), were determined by means of solid phase extraction and reversed-phase liquid chromatography with fluorescence detection (LC-FLD) and reversed-phase liquid chromatography with mass spectrometric detection (LC-MS/MS). The MECs (n = 7 daily composed samples) were 19 to 155 μg L-1 (average: 54 ± 21 μg L-1) and 32 to 99 μg L-1 (average: 65 ± 45 μg L-1) in P1 and P2, respectively. No relevant removal was observed from P1 to P2. In a worst case scenario, the final effluent was regarded as MECs of surface water. These MECs were generally 5 to 20,000-fold higher than what was previously known. If the present data is drawn on to form a model of the situation in developing countries, the picture provides a first rough indication that the environmental risk associated with the use and emission of pharmaceuticals into the environment in developing countries might be higher than in developed countries. © 2008 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

AB - This study was carried out to evaluate the occurrence of the fluoroquinolone antimicrobial agent ciprofloxacin (CIP)in the effluent of the Hospital of the Federal University of Santa Maria (HUSM). Measured environmental concentrations (MECs) of CIP in the hospital wastewater, both before (P1) and after (P2) cesspit/filter system treatment (CFTS), were determined by means of solid phase extraction and reversed-phase liquid chromatography with fluorescence detection (LC-FLD) and reversed-phase liquid chromatography with mass spectrometric detection (LC-MS/MS). The MECs (n = 7 daily composed samples) were 19 to 155 μg L-1 (average: 54 ± 21 μg L-1) and 32 to 99 μg L-1 (average: 65 ± 45 μg L-1) in P1 and P2, respectively. No relevant removal was observed from P1 to P2. In a worst case scenario, the final effluent was regarded as MECs of surface water. These MECs were generally 5 to 20,000-fold higher than what was previously known. If the present data is drawn on to form a model of the situation in developing countries, the picture provides a first rough indication that the environmental risk associated with the use and emission of pharmaceuticals into the environment in developing countries might be higher than in developed countries. © 2008 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

KW - Chemistry

KW - antibiotics

KW - fluoroquinolones

KW - pharmaceuticals

KW - hospital wastewater

UR - http://www.scopus.com/inward/record.url?scp=62349112229&partnerID=8YFLogxK

UR - https://www.mendeley.com/catalogue/ef4ffe0f-4e38-3deb-b93a-bedd4aaf1d45/

U2 - 10.1002/clen.200700171

DO - 10.1002/clen.200700171

M3 - Journal articles

VL - 36

SP - 264

EP - 269

JO - Clean - Soil, Air, Water

JF - Clean - Soil, Air, Water

SN - 1863-0650

IS - 3

ER -

DOI