Localized accelerated degradation of magnesium: A new insight into the mechanism of its biomedical degradation

Research output: Journal contributionsJournal articlesResearchpeer-review

Standard

Localized accelerated degradation of magnesium: A new insight into the mechanism of its biomedical degradation. / Zhang, Yue; Yan, Kai; Xu, Wen et al.
In: Corrosion Science, Vol. 237, 112335, 15.08.2024.

Research output: Journal contributionsJournal articlesResearchpeer-review

Harvard

Zhang, Y, Yan, K, Xu, W, Wang, C, Qian, K, Shao, Y, Jiang, G, Liu, H, Ju, J, Höche, D, Chu, C, Huang, Y, Willumeit-Römer, R, Xue, F, Hort, N & Bai, J 2024, 'Localized accelerated degradation of magnesium: A new insight into the mechanism of its biomedical degradation', Corrosion Science, vol. 237, 112335. https://doi.org/10.1016/j.corsci.2024.112335

APA

Zhang, Y., Yan, K., Xu, W., Wang, C., Qian, K., Shao, Y., Jiang, G., Liu, H., Ju, J., Höche, D., Chu, C., Huang, Y., Willumeit-Römer, R., Xue, F., Hort, N., & Bai, J. (2024). Localized accelerated degradation of magnesium: A new insight into the mechanism of its biomedical degradation. Corrosion Science, 237, Article 112335. https://doi.org/10.1016/j.corsci.2024.112335

Vancouver

Zhang Y, Yan K, Xu W, Wang C, Qian K, Shao Y et al. Localized accelerated degradation of magnesium: A new insight into the mechanism of its biomedical degradation. Corrosion Science. 2024 Aug 15;237:112335. doi: 10.1016/j.corsci.2024.112335

Bibtex

@article{bc7770333bf7424590b148d1b6076add,
title = "Localized accelerated degradation of magnesium: A new insight into the mechanism of its biomedical degradation",
abstract = "Inhomogeneous degradation of Mg results in a potential safety risk for the application of its implants. The particular concern is the occurrence of localized accelerated degradation of Mg under the relatively enclosed condition. The present work investigated such a phenomenon using the Mg-4Zn tube in artificial blood plasma. Its occurrence mechanism was explored through elaborate experiments, including the hydrodynamic platform, real-time electrochemical detection, COMSOL simulation, and morphological observations. It is found the deficiency of Ca2+ and PO43+ in the localized solution induced by the excessively high pH value was responsible for its occurrence.",
keywords = "Artificial blood plasma, Corrosion behavior, Local environment, Magnesium tube, Engineering",
author = "Yue Zhang and Kai Yan and Wen Xu and Cheng Wang and Kun Qian and Yi Shao and Genzhi Jiang and Huan Liu and Jia Ju and Daniel H{\"o}che and Chenglin Chu and Yuanding Huang and Regine Willumeit-R{\"o}mer and Feng Xue and Norbert Hort and Jing Bai",
note = "Publisher Copyright: {\textcopyright} 2024",
year = "2024",
month = aug,
day = "15",
doi = "10.1016/j.corsci.2024.112335",
language = "English",
volume = "237",
journal = "Corrosion Science",
issn = "0010-938X",
publisher = "Elsevier B.V.",

}

RIS

TY - JOUR

T1 - Localized accelerated degradation of magnesium

T2 - A new insight into the mechanism of its biomedical degradation

AU - Zhang, Yue

AU - Yan, Kai

AU - Xu, Wen

AU - Wang, Cheng

AU - Qian, Kun

AU - Shao, Yi

AU - Jiang, Genzhi

AU - Liu, Huan

AU - Ju, Jia

AU - Höche, Daniel

AU - Chu, Chenglin

AU - Huang, Yuanding

AU - Willumeit-Römer, Regine

AU - Xue, Feng

AU - Hort, Norbert

AU - Bai, Jing

N1 - Publisher Copyright: © 2024

PY - 2024/8/15

Y1 - 2024/8/15

N2 - Inhomogeneous degradation of Mg results in a potential safety risk for the application of its implants. The particular concern is the occurrence of localized accelerated degradation of Mg under the relatively enclosed condition. The present work investigated such a phenomenon using the Mg-4Zn tube in artificial blood plasma. Its occurrence mechanism was explored through elaborate experiments, including the hydrodynamic platform, real-time electrochemical detection, COMSOL simulation, and morphological observations. It is found the deficiency of Ca2+ and PO43+ in the localized solution induced by the excessively high pH value was responsible for its occurrence.

AB - Inhomogeneous degradation of Mg results in a potential safety risk for the application of its implants. The particular concern is the occurrence of localized accelerated degradation of Mg under the relatively enclosed condition. The present work investigated such a phenomenon using the Mg-4Zn tube in artificial blood plasma. Its occurrence mechanism was explored through elaborate experiments, including the hydrodynamic platform, real-time electrochemical detection, COMSOL simulation, and morphological observations. It is found the deficiency of Ca2+ and PO43+ in the localized solution induced by the excessively high pH value was responsible for its occurrence.

KW - Artificial blood plasma

KW - Corrosion behavior

KW - Local environment

KW - Magnesium tube

KW - Engineering

UR - http://www.scopus.com/inward/record.url?scp=85199940354&partnerID=8YFLogxK

U2 - 10.1016/j.corsci.2024.112335

DO - 10.1016/j.corsci.2024.112335

M3 - Journal articles

AN - SCOPUS:85199940354

VL - 237

JO - Corrosion Science

JF - Corrosion Science

SN - 0010-938X

M1 - 112335

ER -