Entry of biocides and their transformation products into groundwater via urban stormwater infiltration systems
Publikation: Beiträge in Zeitschriften › Zeitschriftenaufsätze › Forschung › begutachtet
Standard
in: Water Research, Jahrgang 144, 01.11.2018, S. 413-423.
Publikation: Beiträge in Zeitschriften › Zeitschriftenaufsätze › Forschung › begutachtet
Harvard
APA
Vancouver
Bibtex
}
RIS
TY - JOUR
T1 - Entry of biocides and their transformation products into groundwater via urban stormwater infiltration systems
AU - Hensen, Birte
AU - Lange, Jens
AU - Jackisch, Nicole
AU - Zieger, Franziska
AU - Olsson, Oliver
AU - Kümmerer, Klaus
N1 - The authors thank Jens Robertson and Philipp Knobloch for their extensive support in the laboratory analysis. This research was funded by the Federal Ministry of Education and Research (BMBF) ( 02WRM1366A ) support measure “Regional water resource management (ReWaM)” in the project MUTReWa (Measures for a sustainable approach to pesticides and their transformation products in the regional water management). Appendix A
PY - 2018/11/1
Y1 - 2018/11/1
N2 - Biocides are, inter alia, applied as preservatives on facades to prevent the growth of microorganisms. Their incomplete mineralization results in new compounds, so-called transformation products (TPs). Rain causes that both applied biocides and their TPs leach from facades with stormwater into the urban aquatic environment. This study is the first to investigate the introduction of the biocides Diuron, Terbutryn, and Octylisothiazolinone (OIT) and their TPs into the groundwater via urban stormwater infiltration systems. In this study, the TPs of these biocides were created by laboratory photolysis and elucidated using LC-HRMS. The results were then used to analyze TPs by LC-MS/MS in stormwater and groundwater samples, which were taken from an urban swale-trench system and from groundwater wells upgradient and downgradient of the infiltration system. A sprinkling experiment was conducted to evaluate facades as a contamination source. Biodegradation tests were conducted to determine bio-persistence of biocides and their TPs. Fourteen TPs were identified under laboratory photolysis. TP-186, TP-210, and TP-256 of Terbutryn were hitherto unknown. Nine TPs were qualitatively detected in environmental water samples. Parent compounds, TP-219 of Diuron and TP-212, TP-214, and TP-226 of Terbutryn were detected at a maximum concentration of 140 ng L−1 during stormwater events. Concentrations in groundwater were considerably below German drinking water limits, but were higher in groundwater samples downgradient from the investigated swale-trench system than in those collected upgradient. Neither the biocides nor most of their TPs were readily biodegradable under simulated surface water conditions. The results show that entry of biocides and their TPs into groundwater is caused by infiltration of urban stormwater.
AB - Biocides are, inter alia, applied as preservatives on facades to prevent the growth of microorganisms. Their incomplete mineralization results in new compounds, so-called transformation products (TPs). Rain causes that both applied biocides and their TPs leach from facades with stormwater into the urban aquatic environment. This study is the first to investigate the introduction of the biocides Diuron, Terbutryn, and Octylisothiazolinone (OIT) and their TPs into the groundwater via urban stormwater infiltration systems. In this study, the TPs of these biocides were created by laboratory photolysis and elucidated using LC-HRMS. The results were then used to analyze TPs by LC-MS/MS in stormwater and groundwater samples, which were taken from an urban swale-trench system and from groundwater wells upgradient and downgradient of the infiltration system. A sprinkling experiment was conducted to evaluate facades as a contamination source. Biodegradation tests were conducted to determine bio-persistence of biocides and their TPs. Fourteen TPs were identified under laboratory photolysis. TP-186, TP-210, and TP-256 of Terbutryn were hitherto unknown. Nine TPs were qualitatively detected in environmental water samples. Parent compounds, TP-219 of Diuron and TP-212, TP-214, and TP-226 of Terbutryn were detected at a maximum concentration of 140 ng L−1 during stormwater events. Concentrations in groundwater were considerably below German drinking water limits, but were higher in groundwater samples downgradient from the investigated swale-trench system than in those collected upgradient. Neither the biocides nor most of their TPs were readily biodegradable under simulated surface water conditions. The results show that entry of biocides and their TPs into groundwater is caused by infiltration of urban stormwater.
KW - Facade coatings
KW - Groundwater contamination
KW - Leaching
KW - Qualitative TP-screening
KW - Stormwater events
KW - Chemistry
UR - http://www.scopus.com/inward/record.url?scp=85050572105&partnerID=8YFLogxK
U2 - 10.1016/j.watres.2018.07.046
DO - 10.1016/j.watres.2018.07.046
M3 - Journal articles
C2 - 30059904
AN - SCOPUS:85050572105
VL - 144
SP - 413
EP - 423
JO - Water Research
JF - Water Research
SN - 0043-1354